Water > Water - Cross Connection Control Program

Water - Cross Connection Control Program

Cross Connection Control Program

           Cross Connection Control Brochure

 Overview
The City of West Bend Water Utility system delivers safe, high-quality drinking water every day. To continue to
protect the public health and keep the water system safe from contaminants and pollutants we are required by
the Wisconsin Department of Natural Resources, Wisconsin Department of Commerce, and the City of West
Bend Municipal Code to maintain a cross connection control program.

The City of West Bend Water Utility has contracted with Hydro Designs, Inc. (HDI), of Troy, Michigan, and
Brookfield, Wisconsin to manage our program. HDI is an environmental services firm that specializes in
backflow prevention and cross connection control. They currently manage program services for over 80
municipalities and water utilities in Michigan and Wisconsin.

Over the next three years representatives from HDI will perform the initial inspections of all commercial and
industrial buildings throughout the city to detect actual & potential cross connections and make
recommendations for the installation of backflow prevention devices or assemblies where necessary. This will
help ensure that contaminated or polluted water cannot backflow into clean drinking water.

What Is a Cross Connection Control Program?
This is a combined cooperative effort between plumbing and health officials, municipalities, and property
owners to establish and administer guidelines for controlling cross connections and ensure their enforcement
so that the public drinking water supply is protected both in the city water distribution system and within
buildings to the point of use.

Our program consists of the following components:

  • Public Education Program—We will inform our water customers with newsletters, brochures, public awareness meetings, cable access channel programming , and access to informational videos. Visit the following web site for more information and resources:

Hydro Designs, Inc.: www.hydrodesignsinc.com/wiccc

  • Cross Connection Survey—All industrial, commercial, and institutional facilities’ plumbing systems will be inspected to determine if cross connections exist.
  • Installation of Protective Devices—Backflow prevention devices or assemblies will need to be installed where known unprotected cross connections exist.
  • Annual testing—All backflow prevention assemblies will be tested once a year by certified testers.


What Is a Cross Connection?
A cross connection is a direct or potential connection between any part of the public water supply system and a
source of contamination or pollution. The most common form of cross connection is a garden hose, which is
easily connected to the public water supply system and can be used to apply a variety of potentially dangerous
substances, including chemicals and fertilizer. Other common cross connections include dishwashers, toilets,
pressure washers, boilers, pools, and lawn sprinkler systems.

How Does Contamination Occur?
Water normally flows in one direction, from the public water system through the customer’s cold or hot water
plumbing system to a faucet or other plumbing fixture. Under certain conditions, water can flow in the reverse
direction. This is known as backflow, and it occurs when backsiphonage or backpressure is created in a water
line.

Backsiponage may occur when there is a drop in the supply pressure of the water distribution system. This
can be caused by a water line break, water main repair, or during a rapid withdrawal of water from a fire
hydrant. This creates a vacuum, which may pull or siphon contaminants or pollutants into the drinking water
supply.

Backpressure may be created when a source of pressure, such as a pump, boiler, or other building creates a
pressure greater than that supplied from the water distribution system; this may force water to reverse
direction.

What is a Cross Connection Survey?
The cross connection survey is the first step in our program. Wisconsin Department of Natural Resources
Regulations (NR 811.09) recommends that all industrial, commercial, and institutional facilities be surveyed for
cross connections regularly (every two to six years depending on the degree of hazard within the facility).
A survey is a walk-through of the water-system piping in a building or property, starting at the water meter and
ending at the last free-flowing tap. Survey time varies depending upon the facility being surveyed. Large,
complex facilities will be required to prove that they have an internal program to protect the potable water
system. At the end of the survey HDI will produce a report describing any violations or discrepancies found, as
well as a time frame for compliance.

Surveys of existing facilities will be scheduled based on the degree of hazard that they present to the water
system. The first round of inspections will include city-owned buildings, public school facilities,
hospitals/medical facilities, car washes, industrial/manufacturing facilities, and mortuaries. Inspection notices
will be mailed to water customers approximately two weeks before the scheduled inspection date. A building
representative should be available during the inspection to answer questions and provide access to areas
within the facility.

Questions?
Cross connection control program questions can be directed to John Hemauer, City of West Bend Water Utility
Manager at (262) 335-5040 or Hydro Designs, Inc. at (800) 690-6651, press “1.”

  

 

 


West Bend City Hall
1115 S. Main Street
West Bend, WI 53095
(262) 335-5100